A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX420 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX420 (420)   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS EX420 Autoranging MultiMeter

The Extech EX420 Averaging, autoranging DMM with large digit LCD display and temperature function. Features AC/DC Voltage & Current, Resistance, Capacitance, Frequency, Temperature, Diode/Continuity, Duty Cycle. Type K temperature measurements. Data hold, Relative, Auto power off. Specifications. Specifications. DC Voltage Ranges: 400mV, 4V, 40V, 400V, 1000V. DC Voltage Maximum Resolution: 0.1 mV. DC Voltage Accuracy: ± (0.3% reading + 2 digits) @ 400 mV. AC Voltage Ranges: 400mV, 4V, 40V, 400V, 750V. AC Voltage Maximum Resolution: 0.1 mV. AC Voltage Accuracy: ± (1.5% reading + 15 digits) @ 400 mV 50 to 400Hz. DC Current Ranges: 400µA, 4000µA, 40mA, 400mA, 4 A, 20A. DC Current Maximum Resolution: 0.1 µA. DC Current Accuracy: ±(1.5% + 3d) @ 400µA, 4000µA, 40mA, 400mA. AC Current Ranges: 400µA, 4000µA, 40mA, 400mA, 4A, 20A. AC Current Maximum Resolution: 0.1 µA. AC Current Accuracy: ±(1.8% reading + 8 digits) @ 400µA, 4000µA, 40mA, 400mA 50 to 400Hz. Resistance Ranges: 400, 4k, 40k, 400k, 4M, 40Mohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Accuracy: ± (0.8% reading + 4 digits) @ 400 ohm. Capacitance Ranges: 40 nF, 400 nF, 4 µF, 40 µF, 100 µF. Capacitance Maximum Resolution: 0.01 nF. Capacitance Accuracy: ±(5.0% reading + 7 digits) @ 40 nF. Frequency: 0.001Hz to 10MHz. Frequency Accuracy: ±(1.5% reading + 5 digits) @ 5, 50 Hz range. Duty Cycle: 0.1% to 99.9%. Duty Cycle Maximum Resolution: 0.1%. Duty Cycle Accuracy: ±(1.2% reading + 2 digits). Temperature Ranges: -4 to 1382°F (-20 to 750°C ). Temperature Maximum Resolution: 1°F/°C. Temperature Accuracy: ±(3.0% reading + 3 digits) (probe accuracy not included). Diode Test: Test current of 0.3mA typical, open circuit voltage 1.5V DC typical. Continuity Check: Audible signal will sound if the resistance is less than 150 ohm (approx.), test current <0.3mA. Display: 4000 count backlit liquid crystal.



 

Standard Calibration $70.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS EX420. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your EXTECH INSTRUMENTS EX420 CALIBRATION and/or EXTECH INSTRUMENTS EX420 Autoranging MultiMeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: